Brand name: | Saeco |
Type: | Fully Automatic bean to cup |
Model: | Exprelia |
Date: | 04-04-2017 |
Hi,
I have a saeco exprelia which displays MAX BREW GROUP PRESSURE then defaults to a 04 Error messsage. I have bypassed the brew group to return the brew drive to the home position, however drive motor does not return to home position. Instead the drive shaft keeps turning. What part is likely to be the cause of this?
Hi,
This fault is likely to be caused by a faulty gearbox micro switch(es). However they barely go wrong on their own unless something made them fail, such as a leak usually.
Check the micro switches with a multi meter before ordering a new one
Our expert answer program is powered by positive feedbacks, shares and likes on social media and Google from customers just like you.
Please give us a feedback to keep our expert answer service free for others and yourself in the future by liking us on Facebook, following us on Twitter, subscribing to our YouTube channel or sharing your opinion with others on Googe+!
Any of the above help from you is much appreciated.
Saeco Vienna Superautomatica | I need a new micro switch | 10-02-2016 | > |
Saeco Aulika | water | 19-04-2016 | > |
Saeco Magic De Luxe | Water leak problem! | 16-05-2016 | > |
Saeco Saeco Primea Touch Plus | saeco error on dusplay and it beeps | 17-05-2016 | > |
Saeco Incanto De Luxe | No liquid coffee from coffee dispenser | 18-05-2016 | > |
Saeco Incanto De Luxe | No liquid coffee from coffee dispenser | 22-05-2016 | > |
Saeco Incanto De Luxe | Brew Unit 180 degrees out | 23-05-2016 | > |
Saeco other... | Grinder - no coffee beans are grind | 07-06-2016 | > |
Saeco Vienna Superautomatica | Drive motor 180deg. out of align. | 15-06-2016 | > |
Saeco Incanto Sirius | short circuit | 24-06-2016 | > |
Saeco Talea Ring | Talea Ring screen blinking blank & switching modes by itself | 12-08-2016 | > |
Saeco Odea Go | The coffee is not strong enough | 13-09-2016 | > |
Saeco other... | No water to brew unit | 25-09-2016 | > |
Saeco Exprelia | System Error | 25-10-2016 | > |
Saeco Incanto Sirius | Fault. Fill coffee cont | 13-12-2016 | > |
Saeco Incanto Rondo | Leaking water | 19-01-2017 | > |
Saeco Odea Giro | Heating element and Dregsdrawer lights flashing | 06-02-2017 | > |
Saeco Intuita | Too Much Coffee Comes Out of Saeco Intuita No Matter which Button is Pushed | 17-02-2017 | > |
Saeco Exprelia | Water circuit EO5 display | 09-03-2017 | > |
Saeco Incanto De Luxe | brew unit missing | 28-04-2017 | > |
Saeco Odea Giro | Saeco Odea Giro FAST Blinking Red Light | 08-07-2017 | > |
Saeco Exprelia | Saeco exprelia error: Restart to Solve E05 | 25-09-2017 | > |