★ Do you need spare parts? ★
We have a huge range of replacement parts for your Saeco Royal Exclusive Coffee Maker.
Visit our online store here >
Guide to troubleshoot your Saeco Royal Exclusive Coffee Machine
Electricity related issues
- Not turning on
-
Cable and cable fuse
It is really rare for the fuse to go, but can happen in case of a shorted component.
Check the fuse in the plug. Make sure the plug is properly connected into the connector slot.
Door microswitch
A deformed door can eventuate in the switch not beeing pressed, and although this is a rare fault, it's still more frequent than the switch beeing actually faulty.
Make sure the service door is properly closed and the flap pressing the door microswitch is not deformed.
Electric panel
If the electric board turns out to be the source of the problem, then in most cases it's a fuse or the transformer that is responsible for the symptom.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Not heating up
-
Unfortunately all possible causes need the attention of a professional.
Thermostat(s)
The most common cause is either a faulty heating element or a faulty safety thermo-fuse.
Temperature sensor
Although rarely, but the temperature sensor can cause this fault as well.
Electric board
Ocasionally faulty triacs and varistors can cause such a symptom.
- Burnt smell
-
Unfortunately all possible causes need the attention of a professional.
Electric components
Almost any electric component can cause burnt smell.
Electric board
Burnt smell mainly arises from faulty electric boards.
- Lights / error messages
-
Ventilate
This message means that there is no water flow in the system and is mainly caused by a blockage in the water system or the brew unit, or a misplaced water tank.
Fill the water tank and let water through the steam wand till you get a continuous flow and the message disappears from the screen.
Fill watertank
This machine lets you know when the water level is low in the tank.
Fill the water tank.
Brew unit blocked
In case the brew unit couldn't finish the complete cycle in 20 seconds or in case it's blocked by something, You will get this message.
Clean and lubricate brew unit.
Coffee beans empty
If the machine can't fill the scale in 20 seconds, it will give You this message, meaning that the container is either empty or the grinder blades are blocked by greasy or wet coffee.
Fill the coffee beans container.
Clean and readjust grinder.
Grinder blocked
You get this message in case there is a foreign object blocking the grinder or in case the grinder is faulty.
Clean and readjust grinder.
Brew unit missing
If You don't put the brew unit back with a firm movement, then it might not sit back correctly in place and as a result it would most likely not press the microswitch sensing it's presence.
Make sure the brew unit is correctly in place.
Dregdrawer missing
In most cases this symptom is caused by a factory flaw of the series. The dump box microswitch was placed in a way which makes it possible that the dump box can easily slip out from underneath the switch by the slightest movement of the box.
Check the dump box, it might not be correctly in place.
Dregdrawer full
The machine counts the number of coffees made since the last time the signal came up and the dump box was emptied and after about 20 coffees it will give the signal to empty it again, even if You have emptied it in between the two signals.
Empty the dump box.
Overtemperature
This mainly occurs with single boiler machines after steaming with them, because the boiler needs to be cooled down to coffee temperature.
Let water through the steam wand to cool the machine down.
Replace water filter
In case You use the water softener cartridges instead of descaling the machine, then You need to replace it if this sign comes up.
Replace the water softener cartridge.
Decalcify
The machine measures the amount of water that ran through the system since the last time the signal was resetted, and depending on the water hardness level settings, it will give the signal again after the pre-programmed amount of water ran through the system again.
Descale the machine.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
Water related issues
- Leaking
-
Dirty water
This problem is mainly caused by ground coffee piling up in the drainage vent, blocking the path of the excess water let out by the overpressure or the boiler valve.
Clean and lubricate brew unit.
Clean the drainage vent behind the brew unit thoroughly.
Clear water
This is a clear sign of a leaking water system. We strongly advise to stop operating the machine as soon as You come across with this fault.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Fill water tank
-
Check float (magnet)
Some times the magnet (float) in the tank gets stuck or gets filled with water and it either does not float anymore or the magnet inside corrodes to a degree in which it looses its magnetic properties.
Check if there is something restricting the free movement of the float in the water tank.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- No water / coffee through the machine
-
Airlock
This symptom is mostly accompanied by the "Ventilate" message and means that the filling of the water system is required.
Fill the water tank and let water through the steam wand till you get a continuous flow and the message disappears from the screen.
Water working, but no coffee
In cases, where You can't get coffee out of the machine even though You get water through the steam wand, the most common cause is a blocked, dirty brew unit.
Clean and lubricate brew unit.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Not steaming
-
Frother blocked
You need to keep in mind, that all frothers need to be cleaned straight away after use, otherwise milk residue will build up and block the frothing compartment.
Clean the frother attachment and steam wand.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
Brew unit related issues
- Brew unit blocked
-
Brew unit is clogged up
The brew unit is the heart of the machine and it is recommended to be cleaned once a week under running water.
Clean and lubricate brew unit.
Brew unit stuck
This mainly happens when the user tries to force the brew unit out without reseting it to neutral position.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Can't replace the brew unit
-
Gears are not aligned
This fault mainly occurs when the user removes the dump box and/or the brew unit before the machine could reset itself to neutral position.
Put the brew unit aside and everything else back to their places, close the service door and turn the machine off and then on, wait till the machine stands completely still and you should be able to replace the brew unit.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Unusual noises from the brew unit
-
Clicking / cracking sound
Mostly a sound generated by the brew unit and it is a sign of the lack of lubrication.
Clean and lubricate brew unit.
Gearbox damaged
In extreme cases, the lack of lubrication can even lead to overexerting and damaging the gearbox.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Slow brew unit operation
-
Brew unit clogged up
The fault might simply originate from the lack of maintenance, caused by piled up ground coffee blocking the operation of the brew unit.
Clean and lubricate brew unit.
Electric board
A rather frequent issue with these machines is an electric board failure that causes the gearbox motor to operate slowly, thereby exceeding the timeframe of operation and resulting in a blocked brew unit symptom.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
Ground coffee related issues
- Puck consistence
-
Pucks are falling apart
The ground coffee can't stay together as a puck if it's too coarse or the quantity of ground coffee is too low.
Readjust the grinder to grind finer.
Set the ground coffee quantity higher.
Pucks are muddy
The puck becomes muddy if the ground coffee is too fine and water can't pass through it.
Readjust the grinder to grind coarser.
Set the ground coffee quantity higher.
Clear and lubricate brew unit.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Unused coffee in waste
-
Ocasionally
The ground coffee quantity is probably set too high.
Clean and lubricate brew unit.
Clean and readjust grinder.
Frequently
The ground coffee fineness is probably set too coarse and the brew unit can't compress it to a puck.
Clean and lubricate brew unit.
Clean and readjust grinder.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Water in dump box
-
Clean water
Clean water mostly gets in the dump box in larger quantities if the brew unit is not properly cleaned.
Clean and lubricate brew unit.
Coffee
In case coffee ends up in the dump box, that means the brew unit is damaged.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Spilled ground coffee
-
Small amount
All automatic machines spill some ground coffee around the brew unit. You need to clean and lubricate the brew unit on a regular basis to keep the machine running and clean.
Clean and lubricate brew unit.
Large amount
This maily occurs because of the brew unit as symptom of the lack of lubrication.
Clean and lubricate brew unit.
Clean and readjust grinder.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Not grinding coffee
-
Grinder operating, but not grinding the beans
In the vast majority of the cases this symptom is caused by either some kind of liquid that was poured into the grinder or greasy coffee beans. Both result in ground coffee stuck to the blades making them unable to grind the coffee.
Clean and readjust grinder.
Grinder does not operate
The grinder is either blocked by some foreign object or the motor might be worn out or faulty.
Clean and readjust grinder.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
End product related issues
- Coffee dripping
-
Brew unit clogged up
A possible problem is that the shower disc is blocked by coffee residue.
Clean and lubricate brew unit.
The ground coffee is too fine
The grinder fineness settings might be too fine and water can't pass through the ground coffee, or the ground coffee is so fine, that it can block the shower disc.
Readjust the grinder to grind coarser.
Set the ground coffee quantity lower.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Coffee is running through and comes out weak
-
The ground coffee is too coarse
This might happen if the blades are worn, but they can probably be redajusted.
Readjust the grinder to grind finer.
Set the ground coffee quantity higher.
Wrong beans
The beans might be stale or the percentage of arabica beans in the blend might be too high. For these machines we reccomend at least 40% robusta percentage.
Try different beans.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Coffee temperature
-
Too high
The temperature might be too high in case the system has a larger amount of limescale built up inside.
Descale the machine.
Lukewarm
Oddly enough in most cases this issue is not related to the machine at all. It is rather related to the cold mug or cup the user brews the coffee into.
Pre-heat the cup before brewing coffee.
Cold
This is a rare issue, mainly caused by a faulty temperature sensor.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Coffee consistence
-
Weak
The strength of the coffee is influenced by the coffee blend, the ground coffee fineness and quantity, the temperature and the pressure. A weak coffee might be the result of stale beans or too high arabica percentage, coarse ground coffee, low ground coffee quantity, low temperature, or a combination of these.
Readjust the grinder to grind finer.
Set the ground coffee quantity higher.
Try different beans.
Strong or sour
The strength of the coffee is influenced by the coffee blend, the ground coffee fineness and quantity, the temperature and the pressure. A strong coffee might be the result of high robusta percentage, fine ground coffee, high ground coffee quantity, high temperature, or a combination of these.
Readjust the grinder to grind coarser.
Set the ground coffee quantity lower.
Try different beans.
There is no crema on top
In the world of automatic machines the theme crema will be somewhat simplified because of the low number of factors the user can influence and the low precision value of these adjustments. Basically there are three adjustable factors that have the most influence on the crema in a correctly operating automatic machine. These three factors are the coffee beans, the grinding fineness and the ground coffee quantity. The higher robusta percentage, the finer the ground coffee and the higher the coffee quantity is, the thicker the crema will turn out to be.
Readjust the grinder to grind finer.
Set the ground coffee quantity higher.
Try different beans.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.
- Milk froth consistence
-
Milk warms up, but is not froted
If You have steam pressure, but the milk is not frothed, then the problem can only be with the frother device. The most common problem is that the frother is not perfectly clean. You need to make sure to keep the frother attachment completely clean.
Clean the frother attachment and steam wand.
Descale the machine.
In case You can't or don't want to resolve the problem with the tips above, then the machine needs the attention of a professional.